Customer Service & Support: +49 2452 962-450

Business inquiries: +49 2452 962-400

Mon – Fri: 8:00 – 17:00 (CET)

BZ30 CO₂ Air Quality Data Logger
  1. Products & Services
  2. Measuring devices
  3. Climate
  4. Climate data loggers
  5. BZ30 CO2 Air Quality Data Logger

BZ30 CO2 Air Quality Data Logger

For autonomous long-term recording of indoor air quality

Autonomous long-term recording of carbon dioxide concentration, room temperature and humidity

This CO2 air quality data logger is the ideal combination measuring device for architects, experts and every heating, ventilation and air conditioning engineer.

The BZ30 provides you with all functions and equipment features of the BZ25 and is further equipped with a large data memory for 50,000 measured values for the long-term recording of carbon dioxide concentrations, air temperature and humidity values in freely definable measuring intervals from 1 second to 12 hours.

The recorded data can be conveniently transferred to the connected PC via a fast USB connection and there analysed and logged using the analysis software included in the scope of delivery.

Owing to the integrated Li-Ion battery, the BZ30 is also suited for mobile application in addition to the stationary table installation.

The simultaneous recording of humidity and temperature values plus CO2 concentrations offers property managers or landlords optimal possibilities to monitor the ventilation habits.

Automatic baseline calibration

The expected CO2 fresh air value is about 400 ppm (0.04 %vol) nowadays. The device assumes this value to be the lowest limit value (baseline). Over several days, a special algorithm now permanently checks the lowest CO2 value measured of the sensor over a preconfigured time interval and slowly corrects every long-term drift determined by comparison with the expected fresh air value of 400 ppm (or 0.04%vol) CO2. In normal indoor applications, the carbon dioxide level usually decreases almost to outdoor air level at some point during one week. By recording the values over a period of 8 days and then comparing the lowest value to the 400 pm point, the device determines whether or not it needs to adjust the zero point. This takes place fully automatically. The algorithm therefore makes use of the fact that the CO2 content in buildings and rooms regularly stabilises at a minimum for a certain period of time when they are not occupied. In rooms that are continuously occupied or where there is a constantly increased CO2 concentration (e.g. in greenhouses), this principle of automatic balancing therefore does not work.

BZ30 – Special equipment features

CO2 Air Quality Data Logger BZ30
Dimensions
CO2 Air Quality Data Logger BZ30
Side view
CO2 Air Quality Data Logger BZ30
Power supply: internal (battery) 1 x 3.7 V Li-Ion battery or 230 V power supply unit
CO2 Air Quality Data Logger BZ30
USB interface for measuring data transfer

Accurate and permanently stable NDIR measurement of carbon dioxide concentrations in the room air

CO2 Air Quality Data Logger BZ30
Simultaneous display of CO2 values, room temperature, humidity, date and time
CO2 Air Quality Data Logger BZ30
Minimum and maximum value function for CO2, air temperature and humidity
CO2 air quality data logger BZ30
Carbon dioxide alarm function with acoustic alarm signal for freely definable limit values
CO2 Air Quality Data Logger BZ30
Free standing or wall mounted

All Climate data loggers in direct comparison:

To find the Climate data logger which exactly meets your requirements, please consult the concise overview of all Climate data loggers from Trotec, which we're providing to you here so that you can compare them directly to each other.

Models which you do not wish to include in your comparison can be easily dismissed with only one click.

Technical data by comparison

A few practical benefits:

  • Accurate and permanently stable NDIR measurement of carbon dioxide concentrations in the room air
  • Simultaneous display of CO2 values, room temperature, humidity, date and time
  • Minimum and maximum value function for CO2, air temperature and humidity
  • Automatic Baseline Calibration
  • Carbon dioxide alarm function with acoustic alarm signal for freely definable limit values
  • Additional symbolic CO2 indicator display
  • Large backlit display with easily legible measured value indication
  • Autonomous long-term recording of carbon dioxide concentration, room temperature and humidity
  • Storage for 50,000 measured values
  • Freely definable saving interval from 1 second to 12 hours
  • USB interface for measuring data transfer
  • Free standing or wall mounted
  • PC analysis software

Certified safety – calibration of measuring devices according to ISO standard

Being one of the leading full-range suppliers for building diagnostic and environmental measuring equipment, Trotec offers you the possibility to have all measuring devices calibrated, maintained and repaired by a single source. Using a calibrated measuring device you can avoid inaccurate measurement results and reliably protect yourself from possible recourse claims. Hence, play it safe and use our calibration service for your measuring devices: in our own laboratory, we calibrate in compliance with the ISO standard based on strictly defined measuring ranges and points. Optionally, the calibration points can also be defined individually within the specified calibration range.


 standard equipment

 optionally available

 not available

Shop

BZ30 CO2 Air Quality Data Logger show in Trotec online shop

BZ30 CO2 Air Quality Data Logger

You save: 70.00 £

179.95 £ 109.95 £ incl. VAT Show net price (VAT not included)

buy

Technical data

Technical data
General information
  Article number 3.510.205.015
Air temperature [°C]
  Measuring principle | Air temperature NTC
  Min. measuring range | Air temperature [°C] -5
  Max. measuring range | Air temperature [°C] 50
  Display resolution [°C] 0.1
  Accuracy ± | Air temperature [°C] 1
Air temperature [°F]
  Min. measuring range | Air temperature [°F] 23
  Max. measuring range | Air temperature [°F] 122
  Display resolution [°F] 0.1
  Accuracy ± | Air temperature [°F] 1.8
Relative humidity
  Min. measuring range [% RH] 0.1
  Max. measuring range [% RH] 99.9
  Display resolution [% RH] 0.1
  Accuracy [% RH] 5
CO2 concentration
  Measuring principle NDIR
  Min. measuring range | Carbon dioxide [ppm] 0
  Max. measuring range | Carbon dioxide [ppm] 9,999
  Accuracy | Carbon dioxide [ppm] 75
  Accuracy | Carbon dioxide [%] 5
  Accuracy ±75 ppm / ±5 %
  Display resolution [ppm] 1
Display
  LCD
Memory organisation
  Sampling interval > 1 s
  Saving interval > 1 s
  Memory 50,000 Measured values
Interface
  USB
Device control
  Push buttons
Housing design
  Plastics
Power supply
  Internal (battery) 1 x 3.7 V Li-ion battery or 230 V power adapter
  Connection plug Eurostecker EN50075
Dimensions
  Length (packaging excluded) [mm] 90
  Width (packaging excluded) [mm] 110
  Height (packaging excluded) [mm] 98
Weight
  (packaging excluded) [kg] 0.245
Standard scope of delivery
Standard scope of delivery
  Measuring device
  Battery(-ies)
  Power adapter
  USB connection cable
  PC software (download)
  Operating manual
Ascertainable measured values and functions
Internal sensors
  Relative humidity [%]
  CO2 concentration [ppm]
  Air temperature [°C]
  Air temperature [°F]
Functions and features
  Minimum value display
  Maximum value display
  Measured value hold function
  Automatic Baseline Calibration
  Switching function °C/°F
  Backlit display
  CO2acoustic alarm function
  CO2sensor
  Feel-good indication
  Date
  Time

 standard equipment

 optionally available

 not available

Accessories